Prostate volume and PSA density calculator
Enter the three gland dimensions from prostate MRI, or a segmented volume, and the PSA. The calculator gives the gland volume by the ellipsoid formula PI-RADS v2.1 describes, the PSA density, and the size line in the form the PI-RADS report example uses.
Need the whole report too? Type a few findings and get it written ↓
Where the three lengths are measured
A sample dictation is ready below. Press generate, or type your own findings and end with “otherwise normal” to have the rest written out. No signup.
100 free reports over 14 days. No card, nothing to install.
Start your free trial →Please leave out patient identifiers. Text is de-identified before the AI sees it and is not stored. Demo output is not for clinical use.
How to measure
| Dimension | Where it is measured (PI-RADS v2.1, Figure 15) |
|---|---|
| Anteroposterior (AP) | Maximum AP diameter, mid-sagittal T2W image |
| Longitudinal (craniocaudal) | Maximum longitudinal diameter, mid-sagittal T2W image |
| Transverse | Maximum transverse diameter, axial T2W image |
Worked example
The example report in the PI-RADS v2.1 document: a gland of 4.0 × 4.0 × 5.0 cm and a PSA of 12.1 ng/mL.
- Volume = 4.0 × 4.0 × 5.0 × 0.52 = 41.6 mL, reported as 42 mL.
- PSA density = 12.1 ÷ 41.6 = 0.29 ng/mL/mL.
Size line. Size: 4.0 x 4.0 x 5.0 cm for 42 cubic cm, PSA density 0.29 ng/mL/mL.
Notes
- The PI-RADS v2.1 document gives the formula and asks for the volume to be reported; it sets no PSA density threshold. Interpret the density with the clinical context and local practice.
- The formula assumes the gland is roughly ellipsoid. A large median lobe or an irregular gland is measured more faithfully by segmentation.
- Use a PSA measured close to the date of the MRI.
Related
On the same topic
Related calculators
References
- American College of Radiology, European Society of Urogenital Radiology, AdMeTech Foundation. PI-RADS: Prostate Imaging Reporting and Data System, Version 2.1. 2019. acr.org
- Turkbey B, Rosenkrantz AB, Haider MA, et al. Prostate Imaging Reporting and Data System Version 2.1: 2019 Update of Prostate Imaging Reporting and Data System Version 2. Eur Urol 2019;76(3):340-351. doi:10.1016/j.eururo.2019.02.033
Sources last checked November 2026.
MyRadAgent’s radiology AI drafts the full report and applies this guideline automatically, with the category and follow-up in the impression. Free trial runs in the browser: 100 reports over 14 days, no card, no IT ticket.
Try it on a report → or try it here first — no signup ↑BI-RADS, TI-RADS, LI-RADS, PI-RADS, O-RADS, Lung-RADS, CAD-RADS, NI-RADS and ACR are registered trademarks of the American College of Radiology. They are used here only to identify the published systems these tools implement; MyRadAgent is not affiliated with, sponsored by or endorsed by the ACR.