Nodule volume doubling time calculator

Enter the nodule diameter on each study and the interval between scans. Volume scales with the cube of diameter, so modest diameter change means large volume change — the calculator makes that explicit and maps the result to the standard interpretation bands.

Need the whole report too? Type a few findings and get it written ↓

Diameter on first study (mm)
Diameter on follow-up (mm)
Interval between studies (days)
Formula. Volume scales with diameter cubed, so VDT = t · ln 2 / (3 · ln(d₂/d₁)). A 6 mm → 8 mm change is a 2.4× volume increase — diameter understates growth.
Get the whole report from a few sentences.

A sample dictation is ready below. Press generate, or type your own findings and end with “otherwise normal” to have the rest written out. No signup.

Now try it on your own case.

100 free reports over 14 days. No card, nothing to install.

Start your free trial →

Please leave out patient identifiers. Text is de-identified before the AI sees it and is not stored. Demo output is not for clinical use.

Interpretation bands

Doubling timeTypical meaning
VDT < 100 daysRapid growth — typical of aggressive malignancy (also seen with infection/inflammation; correlate clinically).
VDT 100-400 daysThe classic growth range of solid non-small-cell lung cancer — suspicious; tissue diagnosis or PET/CT is usually warranted.
VDT > 400 daysLower probability of malignancy — NELSON treats 400-600 days as intermediate and over 600 days as low; very indolent malignancy is still possible. Note that subsolid adenocarcinoma-spectrum lesions can double over 3-5 years, so long-interval follow-up is still prudent for GGNs.

Caveats

Related

Source. Standard exponential growth model; interpretation per the NELSON trial growth analyses (Horeweg N, et al. Lancet Oncol 2014;15(12):1332-1341). View on PubMed

Frequently asked questions

How is nodule volume doubling time calculated?

Volume doubling time comes from two diameters and the interval between scans, using the exponential growth model: VDT = t × ln 2 / (3 × ln(d2/d1)), where t is the interval in days. The factor of three enters because volume scales with the cube of diameter — a 26% increase in diameter is already a doubling of volume, which is why apparently modest diameter change can represent substantial growth.

What volume doubling time suggests lung cancer?

A VDT of 100-400 days is the classic growth range of solid non-small-cell lung cancer and is suspicious — tissue diagnosis or PET/CT is usually warranted. Under 100 days suggests rapid growth typical of aggressive malignancy, though infection and inflammation can grow that fast too. Over 400 days carries lower probability of malignancy; the NELSON screening analyses treat 400-600 days as intermediate and over 600 days as low.

Does a long doubling time exclude malignancy in a ground-glass nodule?

No. Subsolid adenocarcinoma-spectrum lesions can have volume doubling times of three to five years, far beyond the 400-day benchmark derived from solid cancers, so long-interval follow-up remains prudent for ground-glass nodules even when calculated growth is slow. Conversely, the conventional benignity benchmark — two-year stability — applies to solid nodules; interval shrinkage favors an inflammatory or infectious cause.

This calculator, written into your report for you

MyRadAgent drafts the full report - and applies this guideline automatically, with the category and follow-up in the impression. Free trial runs in the browser: 100 reports over 14 days, no card, no IT ticket.

Try it on a report → or try it here first — no signup ↑
This is a reference implementation of a published guideline, for use by qualified clinicians. It does not account for patient-specific factors and is not a substitute for clinical judgment or a formal radiology consultation. See our full disclaimer.

BI-RADS, TI-RADS, LI-RADS, PI-RADS, O-RADS, Lung-RADS, CAD-RADS, NI-RADS and ACR are registered trademarks of the American College of Radiology. They are used here only to identify the published systems these tools implement; MyRadAgent is not affiliated with, sponsored by or endorsed by the ACR.