MyRadAgent
Home › Tools › NI-RADS lookup: head and neck cancer surveillance

NI-RADS lookup: head and neck cancer surveillance

Pick the modality, the site and the category you assigned to see the ACR definition and the management that goes with it. NI-RADS applies to surveillance after curative-intent treatment of head and neck cancer; the primary site and the neck are scored separately.

Need the whole report too? Type a few findings and get it written ↓

Category and what follows

1Routine surveillance2aDirect inspection2bShort follow-up or PET3Biopsy4Clinical management
Each NI-RADS category with the management the ACR tables attach to it. Bar heights are schematic; the definitions are in the tables below.
Modality
Site
Category assigned
Draft the full report from this finding — free

A sample dictation is ready below. Press generate, or type your own findings and end with “otherwise normal” to have the rest written out. No signup.

Now try it on your own case.

100 free reports over 14 days. No card, nothing to install.

Start your free trial →

Please leave out patient identifiers. Text is de-identified before the AI sees it and is not stored. Demo output is not for clinical use.

Categories, findings and management

Contrast CT or PET/CT: primary site

CategoryMeaningImaging findingsManagement
0Incomplete
  • New baseline study without any prior imaging available AND knowledge that prior imaging exists and will become available as comparison
Assign a score in an addendum after the prior imaging becomes available.
1No evidence of recurrence
  • Expected post-treatment changes
  • Non-mass-like distortion of soft tissues
  • Low-density post-treatment mucosal edema
  • Diffuse linear mucosal enhancement or FDG uptake
Routine surveillance.
2aLow suspicion
  • Focal mucosal enhancement or FDG uptake on the initial post-treatment scan
Direct visual inspection.
2bLow suspicion
  • Deep, ill-defined soft tissue, with only mild or moderate FDG uptake if PET is available
  • Discordance between PET and CECT: a discrete CECT abnormality with little or no FDG uptake, or focal FDG uptake with no CT correlate (applies only if the original tumour was FDG avid)
Short-interval follow-up (3 months), or PET if scoring on CECT alone.
3High suspicion
  • Discrete nodule or mass at the primary site, with intense focal FDG uptake if PET is available
Image-guided or clinical biopsy if clinically indicated.
4Definitive recurrence
  • Pathologically proven or definite radiologic and clinical progression
Clinical management.

Contrast CT or PET/CT: neck nodes

CategoryMeaningImaging findingsManagement
0Incomplete
  • New baseline study without any prior imaging available AND knowledge that prior imaging exists and will become available as comparison
Assign a score in an addendum after the prior imaging becomes available.
1No evidence of recurrence
  • Expected post-treatment changes
  • Residual nodal tissue with no FDG uptake or enhancement
Routine surveillance.
2Low suspicion
  • Mild or moderate FDG uptake in residual nodal tissue, or persistent areas of heterogeneous enhancement
  • Enlarging or new lymph node without definitive abnormal morphologic features
  • Discordance between PET and CECT: enlarging lymph node with little or no FDG uptake (applies only if the original tumour was FDG avid)
Short-interval follow-up (3 months), or PET if scoring on CECT alone.
3High suspicion
  • Residual nodal tissue with intense FDG uptake
  • New enlarged or enlarging lymph node with abnormal morphologic features (new necrosis, or gross extranodal extension invading adjacent structures) on CECT, or focal intense FDG uptake if PET is available
Image-guided or clinical biopsy if clinically indicated.
4Definitive recurrence
  • Pathologically proven or definite radiologic and clinical progression
Clinical management.

MRI (v2025): primary site

CategoryMeaningImaging findingsManagement
0Incomplete
  • New baseline study without any prior imaging available AND knowledge that prior imaging exists and will become available as comparison
Assign a score in an addendum after the prior imaging becomes available.
1No evidence of recurrence
  • Expected post-treatment changes
  • Diffuse thin linear mucosal enhancement or submucosal edema
  • Low T1 and T2 signal suggesting scar or fibrosis
  • Non-mass-like distortion of soft tissues with T2-hyperintense (not T2-intermediate) signal, suggesting edema or inflammation
  • First post-treatment study: resolution of the tumour seen before treatment, with no focal nodular or mass-like soft tissue; decreased soft tissue or enhancement in the skull base foramina and perineural regions
  • Compared with prior post-treatment studies: no new focal nodular or mass-like soft tissue; unchanged or decreased fat-plane effacement and skull base or perineural enhancement
Routine surveillance.
2aLow suspicion
  • Focal non-mass-like mucosal enhancement or focal reduced diffusion
Direct visual inspection.
2bLow suspicion
  • Deep, ill-defined non-nodular soft tissue
  • Soft tissue whose MRI features (DWI, enhancement, T1 and T2 signal) differ from the original tumour
  • Soft tissue with intermediate rather than hyperintense T2 signal and intermediate rather than intense enhancement
  • First post-treatment study: partial resolution of the tumour; unchanged skull base foramina or perineural soft tissue matching the tumour before treatment; new thin smooth skull base or perineural enhancement within the radiation field
Short-interval follow-up MRI or PET. For perineural soft tissue at the skull base, follow-up MRI is preferred over PET.
3High suspicion
  • Discrete nodule or mass at the primary site, especially if new or enlarging AND its signal and enhancement match the original tumour
  • Intense focal FDG uptake if PET is available
  • Increased soft tissue or enhancement in the skull base foramina and perineural regions, increased fat-plane effacement on pre-contrast T1, or increased enhancement and nodular soft tissue along major nerves supplying the primary site
Image-guided or clinical biopsy if clinically indicated. Where biopsy is not feasible (many perineural locations), multidisciplinary discussion is often appropriate.
4Definitive recurrence
  • Pathologically proven or definite radiologic and clinical progression
Clinical management.

MRI (v2025): neck nodes

CategoryMeaningImaging findingsManagement
0Incomplete
  • New baseline study without any prior imaging available AND knowledge that prior imaging exists and will become available as comparison
Assign a score in an addendum after the prior imaging becomes available.
1No evidence of recurrence
  • Expected post-treatment changes
  • Residual nodal tissue that is hypoenhancing in the region of the original node, with no FDG uptake if PET is available
Routine surveillance.
2Low suspicion
  • Residual nodal tissue with persistent areas of heterogeneous enhancement, or mild or moderate FDG uptake if PET is available
  • New or enlarging lymph node without definitive abnormal morphologic features
  • Discordance between PET and MRI: an enlarging node or discrete neck mass with little or no FDG uptake, or focal uptake with no MRI correlate (applies only if the original tumour was FDG avid)
Short-interval follow-up MRI or PET.
3High suspicion
  • Residual nodal tissue with intense FDG uptake, OR definite enlargement or increased enhancement
  • New or enlarging lymph node with necrosis, cystic change, irregular borders, or focal intense FDG uptake if PET is available
Image-guided or clinical biopsy if clinically indicated.
4Definitive recurrence
  • Pathologically proven or definite radiologic and clinical progression
Clinical management.

Using NI-RADS

Related

Source. ACR Neck Imaging Reporting and Data System (NI-RADS): CT/PET-CT tables (2021) and MRI v2025. View the ACR document

Related calculators

References

  1. American College of Radiology. NI-RADS PET/CT Category Descriptors, Imaging Findings, and Management; NI-RADS MRI v2025 Assessment Categories. 2021 and 2025. acr.org
  2. Aiken AH, Rath TJ, Anzai Y, et al. ACR Neck Imaging Reporting and Data Systems (NI-RADS): A White Paper of the ACR NI-RADS Committee. J Am Coll Radiol 2018;15(8):1097-1108. doi:10.1016/j.jacr.2018.05.006
  3. Bunch PM, Aiken AH, Baugnon KL, et al. ACR Neck Imaging Reporting and Data System for MRI Version 2025. J Am Coll Radiol 2025;22(11):1325-1336. doi:10.1016/j.jacr.2025.07.023

Sources last checked November 2026.

This calculator, written into your report for you

MyRadAgent’s radiology AI drafts the full report and applies this guideline automatically, with the category and follow-up in the impression. Free trial runs in the browser: 100 reports over 14 days, no card, no IT ticket.

Try it on a report → or try it here first — no signup ↑
This is a reference implementation of a published guideline, for use by qualified clinicians. It does not account for patient-specific factors and is not a substitute for clinical judgment or a formal radiology consultation. See our full disclaimer.

BI-RADS, TI-RADS, LI-RADS, PI-RADS, O-RADS, Lung-RADS, CAD-RADS, NI-RADS and ACR are registered trademarks of the American College of Radiology. They are used here only to identify the published systems these tools implement; MyRadAgent is not affiliated with, sponsored by or endorsed by the ACR.