Normal AAA Screening Ultrasound Report Template

Normal abdominal aortic aneurysm screening ultrasound report template: maximal outer-to-outer AP and transverse aortic diameters at the suprarenal, infrarenal and bifurcation levels, common iliac arteries, no aneurysm, with notes on the 3 cm threshold, surveillance intervals and the limited-study wording.

EXAMINATION: Ultrasound of the abdominal aorta, screening for
abdominal aortic aneurysm.

CLINICAL HISTORY: [indication, e.g. “Abdominal aortic aneurysm
screening, male age 65-75 with a smoking history”]

COMPARISON: None available.

TECHNIQUE: Grayscale and color Doppler imaging of the abdominal aorta
from the diaphragmatic hiatus to the aortic bifurcation in the
transverse and longitudinal planes, with the common iliac arteries
at their origins. Diameters were measured outer wall to outer wall,
perpendicular to the long axis.

FINDINGS:
Visualization: The abdominal aorta is well visualized throughout its
length [despite / without] bowel gas.
Aortic diameters (outer to outer):
Proximal (suprarenal) aorta: [x] cm AP, [x] cm transverse.
Mid (infrarenal) aorta: [x] cm AP, [x] cm transverse.
Distal aorta (above the bifurcation): [x] cm AP, [x] cm transverse.
Maximal aortic diameter: [x] cm, infrarenal.
Aortic wall and lumen: Normal caliber throughout, tapering normally
to the bifurcation. No focal dilatation, saccular outpouching or
intramural thrombus. [Mild atherosclerotic wall calcification.]
No dissection flap.
Common iliac arteries: Right [x] cm and left [x] cm at the origins.
No iliac aneurysm.
Flow: Normal antegrade color flow throughout the imaged aorta.
Other: No periaortic fluid or mass. [The visualized inferior vena
cava is unremarkable.]

IMPRESSION:
1. Normal caliber abdominal aorta, maximal diameter [x] cm. No
abdominal aortic aneurysm.
2. No further screening is indicated for a negative screening
examination in this age group.

Dictation notes

Never paste a template again

MyRadAgent turns a scratch dictation into this report — structured, guideline-checked, in your own section headers and phrasing. It learns your style from every correction. Free trial: 100 reports over 14 days, no card, no IT ticket.

Draft a report with it → or watch the live demo first — no signup →

← All report templates

This is a reference implementation of a published guideline, for use by qualified clinicians. It does not account for patient-specific factors and is not a substitute for clinical judgment or a formal radiology consultation. Templates are generic scaffolds for licensed radiologists; verify wording against your own practice standards. See our full disclaimer.